Abstract:
Although the application of non-metallic materials in oil field alleviates the corrosion of traditional metal materials, other failures still exist. In this paper, three typical failure cases in Tahe oilfield are analyzed systematically, which are HDPE interpenetrating repair pipeline cracking failure in a transfer station, GFRP flange leakage failure of a combined sewage export pipeline and foaming failure of plastic alloy composite pipe lining used in a well. Therefore, we put forward the basic method of failure analysis and evaluation system of non-metallic pipe used in oil field.