天然气净化厂SCOT尾气处理装置运行及优化

Operation and optimization of SCOT tail gas treatment unit in natural gas purification plant

  • 摘要:
    目的 中国石油西南油气田公司川中油气矿磨溪天然气净化厂现有两套硫磺回收装置,分别采用MCRC和CPS工艺,硫回收率分别为99.0%和99.2%,需进一步提高装置硫回收率,使排放烟气中SO2质量浓度达到GB 39728—2020《陆上石油天然气开采工业大气污染物排放标准》的要求。
    方法 在现有硫磺回收装置的基础上新建一套SCOT尾气处理装置,并结合装置试运行的情况,对影响装置操作稳定性、总硫回收率和污染物排放全时段达标的关键问题进行了分析,针对加氢反应器余热锅炉管壳程窜漏、再生塔频繁拦液等问题归纳了所采取的改造和优化措施。
    结果 新建SCOT尾气处理装置性能考核结果表明:装置总硫回收率达到99.96%,加氢催化剂SO2转化率≥99.9%,加氢催化剂有机硫水解率约93.4%,排放烟气中SO2质量浓度平均值为164.2 mg/m3,贫液中H2S质量浓度平均值为0.14 g/L,考核结果均优于设计值。
    结论 新建尾气处理装置运行平稳,可为同类装置提供参考。

     

    Abstract:
    Objective There are two sets of sulfur recovery units in the Moxi Natural Gas Purification Plant of the Central Sichuan Oil and Gas District, PetroChina Southwest Oil & Gasfield Company, MCRC and CPS processes are used respectively, and the sulfur recovery rate is 99.0% and 99.2%, respectively. It is necessary to further improve the sulfur recovery rate of the units so that the mass concentration of SO2 in the discharged flue gas can meet the requirements of the GB 39728—2020 Emission standard of air pollutants for onshore oil and gas exploitation and production industry.
    Method Based on the existing sulfur recovery units, a new set of SCOT tail gas treatment unit was built. Combined with the trial operation of the unit, the key problems affecting the operation stability of the unit, the total sulfur recovery rate and the full-time compliance of pollutants discharge were analyzed. The modification and optimization measures were summarized for the problems of leakage between the tube side and the shell side of the hydrogenation reactor waste heat boiler and the frequent blocking of the regeneration tower.
    Result The performance evaluation results of the newly built SCOT tail gas treatment unit showed that the total sulfur recovery rate of the unit reached 99.96%, the SO2 conversion rate of the hydrogenation catalyst was not less than 99.9%, the organic sulfur hydrolysis rate of the hydrogenation catalyst was about 93.4%, the average mass concentration of SO2 in the discharged flue gas was 164.2 mg/m3, and the average mass concentration of H2S in the lean liquid was 0.14 g/L. The evaluation results were better than the design values.
    Conclusion The new tail gas treatment unit runs smoothly and can provide a reference for similar units.

     

/