摘要: |
长庆气田的部分甲醇回收装置长期处理偏离设计进料浓度的含醇污水,能耗高,运行不经济。通过分析原料甲醇浓度变化及塔底废水中甲醇含量变化时甲醇回收装置的能耗,并查阅相关标准规范,对甲醇回收装置脱甲醇废水控制指标及污水回注甲醇控制指标给出了建议。 |
关键词: 长庆气田 甲醇污水 甲醇再生装置 能耗 污水回注 |
DOI: |
分类号:X741 |
基金项目: |
|
Analysis of Energy Consumption Impact about Methanol Concentration of the Raw Material and the Tower Bottom Wastewater on Methanol Recovery Device |
Huyan Nianchao, Li Yaping, Zhang Mingli
|
Xi’ an Changqing Technology Engineering Co. , Ltd.
|
Abstract: |
The methanol recovery devices of Changqing gas field have treated methanol bearing sewage deviating from the designed input concentration for a long time, their energy consumption are high. Through the energy consumption of the methanol recovery device while the changing of raw material and the tower bottom wastewater methanol concentration, the relevant standards and specifications are looked up, new proposals of the methanol wastewater con-trol index and the methanol control index in injected wastewater are put forward. |
Key words: Changqing gas field methanol sewage methanol recovery device energy consumption wastewater reinjection |