Abstract:
Objective The field effect evaluation technology of corrosion inhibitor in sour gas field is formed by gas field water analysis and field corrosion monitoring/detection, etc.
Methods The effectiveness of residual concentration analysis of corrosion inhibitor, ultrasonic thickness measurement and electrochemical probe was investigated in the laboratory.
Results The results show that the R2 value of the residual mass concentration of corrosion inhibitor curve is more than 99.9%, the highest relative error of the ultrasonic test result is 0.67%, the electrochemical probe is a sensitive method to evaluate the corrosion inhibitor.
Conclusions The field effect evaluation technology of corrosion inhibitor was applied in a raw gas pipeline in Longwangmiao gas reservoir. The results show this technology can effectively evaluate the field anti-corrosion effect of corrosion inhibitor, and the evaluation results are consistent with the field corrosion detection results.