Strength Computation for Triple-Saddle Support Sulfur Recovery Condenser
-
Abstract
The forced diogram of sulfur recovery condenser with asymmetric arrangement triple - saddle support is analyzed and simplified in this paper, and the mathematical formula for computing the counter force and axial bending moment of each support is present
-
-